Wall Type Indicator Post

The Wall Type Indicator Post (Models MH-1510FA/MH-1510A) is a UL/FM-approved wall-mounted fire hydrant system, designed for reliable water supply in commercial, industrial, and urban public spaces—supporting fire truck and hose connection for efficient fire suppression.

  • Material :

    Ductile Cast Iron
  • Inlet :

    6" (DN150)
  • Working Pressure :

    10 bar (145 PSI)
  • Type :

    Wall Type Indicator Post
  • MOQ :

    20 Pieces
  • Delivery Time :

    15~30 Days

Product Description

 

The Wall Type Indicator Post (MH-1510FA/MH-1510A) is a high-performance wall-mounted fire safety device, engineered to deliver stable, high-pressure water flow for fire suppression. Compliant with AWWA C502 standards and UL/FM approved, it features a durable ductile iron + metal component construction, with red polyurethane (or custom) painting for high visibility.
Equipped with a 6" (DN150) inlet flange and multi-nozzle configuration (1×4.5" pumper nozzle + 2×2.5" hose nozzles), this post supports simultaneous connection of fire trucks and hoses. It includes a dedicated hydrant wrench for operation, and its sealed design + drainage system ensures long-term reliability in outdoor environments. Available in flange (MH-1510FA) or mechanical (MH-1510A) connector options, it adapts to different pipeline installation needs.

Features

  • UL/FM Approved: Meets global fire safety standards (UL 246, FM 1510) for reliable performance.
  • Multi-Nozzle Configuration: 1×4.5" pumper nozzle + 2×2.5" hose nozzles for flexible fire-fighting operations.
  • Dual Connector Options: Flange (ASME B16.5 CLASS 150/DIN 2501 PN16) or mechanical (AWWA/ANSI C153) for pipeline compatibility.
  • High Durability: Ductile iron body + 316 stainless steel/steel 1045 components resist corrosion and impact.
  • Visibility & Customization: Red polyurethane + bitumen black painting (custom colors available) for quick emergency identification.
  • Integrated Drainage: Spring-loaded drain hole ensures residual water discharge to prevent freezing/damage.

Products Parameter

Material Ductile Cast Iron
Inlet Size 6" (DN150)
Main Valve Size 133.4 mm (5-1/4")
Nozzles 1×4.5" (4NH thread) pumper nozzle; 2×2.5" (7.5NH thread) hose nozzles
Connector Options Flange: ASME B16.5 CLASS 150/DIN 2501 PN16; Mechanical: AWWA/ANSI C153
Nominal Pressure 250 PSI
Working Pressure 10 bar (145 PSI)
Testing Pressure 24 bar (348 PSI)
Buried Dimensions (mm) 1063 (3'6"), 1215 (4'), 1368 (4'6"), 1520 (5'), 1673 (5'6"), 1825 (6"), 1978 (6'6"), 2130 (7')

FAQ

  • Q: Can the connecting coupling be customized?
     
    A: Yes, we support custom coupling types to match local pipeline standards.

Q:What is your payment terms?

A:Payment supports T/T, L/C, etc. We also support payment via wechat or Alipay.


  • Q: Is this hydrant suitable for cold regions?
     
    A: Yes—we provide frost-proof versions for cold climates (please specify your region when ordering).

  • Q: Can the water outlet size be customized?
     
    A: Yes, we support custom outlet sizes to match local fire hose standards.
.

Contact us

Act now—stop fire risks at the source!

JINYUAN TECHNOLOGY DEVELOPMENT CO.,LTD

Tel.:86-18159244550   Mobil:18159244550

EMAIL:Jony@jyfire.com.cn

ADD:CHENGGONG TECHNOLOGY ZONE PHASE 3,XIMEI TOWN,NAN'AN QUANZHOU CITY

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.
Submit

Related Products

  • Double Plastic Fire Extinguisher Cabinet – Holds 4.5–9kg ABE/DCP & 3.5kg CO2 Units

    Double Fire Extinguisher Cabinets

    The Double Plastic Fire Extinguisher Cabinet is a durable, versatile storage solution for fire safety, designed to securely house and organize 4.5–9kg ABE/DCP and 3.5kg CO2 fire extinguishers in commercial, industrial, and public spaces.
  • Single Plastic Fire Extinguisher Cabinet – Red/Black Design With Transparent Windows For Quick Inspection

    Single Fire Extinguisher Cabinets

    The Single Plastic Fire Extinguisher Cabinet is a robust, secure storage solution for fire safety, designed to house and protect single fire extinguishers (compatible with standard models) in commercial, industrial, and outdoor environments, ensuring quick access during emergencies.
  • Swing Fire Hose Reel

    Fire Hose Reel

    Fire reels are fixed fire-fighting facilities installed inside buildings, mainly used to extinguish initial fires. It is usually installed in conjunction with the indoor fire hydrant system or set up independently, and is a crucial part of the fire safety system.
  • Automatic Swing Fire Reel – Self-Retracting For Quick Hose Storage

    Swing Series Fire Hose Reel

    The Swing Series Fire Hose Reel is a versatile fire suppression device, available in manual and automatic operation types, designed for rapid hose deployment in initial fire scenarios across commercial, industrial, and public buildings.
  • Ground Fire Hydrant

    Outdoor Ground Fire Hydrant

    Outdoor fire hydrants are key fire-fighting water supply devices set up outside buildings to provide water sources for fire brigades to extinguish fires.
  • 2 Way Pillar Fire Hydrant

    2 Way Pillar Fire Hydrant

    The fire pillar hydrant is a vertical pipe-like structure installed outdoors and is typically painted in a distinctive color for easy identification.  It is usually made of durable materials like cast iron or steel to withstand harsh weather conditions.
  • Wall Type Indicator Post MH-1510FA – 6

    Wall Type Indicator Post

    The Wall Type Indicator Post (Models MH-1510FA/MH-1510A) is a UL/FM-approved wall-mounted fire hydrant system, designed for reliable water supply in commercial, industrial, and urban public spaces—supporting fire truck and hose connection for efficient fire suppression.
  • Fire Hydrant Pressure Reducing Valve - Jinyuan

    Fire Hydrant Pressure Reducing Valve

    The Fire hydrant pressure reducing valve is essential components of fire hydrant system. They are designed to regulate the pressure of water flowing out of fire hydrants and prevent damage to the system and surrounding areas due to excessive water pressure. These valves are installed at strategic locations throughout the fire hydrant system to ensure adequate water pressure is maintained throughout the system.

leave a message

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.
Submit
Contact us :
+86 -18159244550

Home

Products

WhatsApp

contact